The
Adapt/Volume... menu item opens the
Volume Adaption dialog box.
Volume Adaption Dialog Box
The
Volume Adaption dialog box allows you to mark or refine cells based on cell volume or change in cell volume. See Section
27.7 for details.
Controls
Options
contains the radio buttons that toggle between marking and/or refining based on volume magnitude or volume change.
Magnitude
enables the marking/refining of cells based on volume magnitude.
Change
enables the marking/refining of cells based on the change in volume.
Min
displays the minimum value of cell volume or cell volume change in the mesh. This value is not editable.
Max
displays the maximum value of cell volume or cell volume change in the mesh. This value is not editable.
Max Volume
defines the threshold value for marking/refining the mesh based on volume magnitude. Cells that have volumes greater than the threshold are marked for refinement.
Max Volume Change
defines the threshold value for marking/refining the mesh based on the change in volume. Cells with volume changes that are greater than the threshold value are marked for refinement.
Manage...
opens the
Manage Adaption Registers dialog box, which allows you to display and manipulate adaption registers that are generated using the
Mark command.
Adapt
refines the mesh based on either the maximum volume or the volume change, and the adaption limits.
Mark
marks cells to be refined based on either the maximum volume or the volume change. This command produces an adaption register. For information on using adaption registers, see Section
27.11.1.
Compute
calculates the minimum and maximum cell volume or cell volume change and displays them in the
Min and
Max real number fields.