The
Adapt/Gradient... menu item opens the
Gradient Adaption dialog box.
Gradient Adaption Dialog Box
The
Gradient Adaption dialog box allows you to mark or adapt to gradients of a specified field variable. See Section
27.3 for details.
Controls
Options
contains the check buttons that toggle the ability to mark and/or adapt cells for refinement or coarsening.
Refine
toggles the ability to refine or mark cells for refinement.
Coarsen
toggles the ability to coarsen or mark cells for coarsening (available in 2D and axisymmetric cases).
Normalize per Zone
toggles the ability of zonal normalization.
Contours...
opens the
Contours dialog box, which you can use as an aid to selecting adaption thresholds by displaying contours of adaption function.
Manage...
opens the
Manage Adaption Registers dialog box, which allows you to display and manipulate adaption registers that are generated using the
Mark command.
Method
contains options for specifying the criterion for adaption.
Curvature
specifies the use of the second gradient of a field variable for adaption. This approach is recommended for problems with smooth solutions.
Gradient
specifies the use of the first gradient of a field variable for adaption. This approach is recommended for problems with strong shocks.
Iso-Value
allows you to customize the adaption criterion (using custom field functions, user-defined scalars, etc.).
Normalization
contains the options available for normalization.
Standard
specifies that the gradient or curvature is not normalized.
Scale
specifies that the gradient or curvature is scaled by its average value in the domain.
Normalize
specifies that the gradient or curvature is scaled by its maximum value in the domain (i.e. the gradient or curvature is bounded by [0, 1]).
Dynamic
contains options to specify dynamic gradient adaption.
Dynamic
enables dynamic gradient adaption.
Interval
allows you to specify the number of iterations or time-steps between two consecutive automatic mesh adaptions, depending on whether you are performing a steady-state or a time-dependent solution, and on which solver you are using.
Gradients of
contains a list of the field variables that can be used in the gradient adaption function.
Min/Max
displays the minimum and maximum cell values of the gradient adaption function based on the selected quantity.
Coarsen Threshold
designates the threshold values for coarsening the mesh. Cells with adaption function values below the
Coarsen Threshold will be marked for coarsening.
Refine Threshold
designates the threshold values for refining the mesh. Cells with adaption function values above the
Refine Threshold will be marked for refinement.
Adapt
adapts the mesh based on the gradients of the selected scalar quantity, the coarsening and refining toggle buttons and thresholds, and the adaption limits.
Mark
marks cells to be refined and/or coarsened based on the gradients of the selected quantity and the coarsening and refining toggle buttons and thresholds. This command produces an adaption register. For information on using adaption registers, see Section
27.11.1.
Compute
computes the minimum and maximum cell values of the gradient adaption function with the selected scalar quantity. The values are displayed in the
Min and
Max real number fields.