(a)
Select
Yplus if you are using the enhanced wall treatment.
(b)
If you are using wall functions, you can select either type.
2.
Choose the wall zones for which you want boundary cells to be marked or adapted in the
Wall Zones list, and click on
Compute to update the
Min and
Max fields. The values displayed are the minimum and maximum values for all wall zones, not just of those selected.
3.
Set the
Min Allowed and
Max Allowed. Cells with
or
values below
Min Allowed will be coarsened or marked for coarsening, and cells with
or
values above
Max Allowed will be refined or marked for refinement.
4.
(optional) If you want to set any adaption options (described in Section
27.12), click on the
Controls... button to open the
Mesh Adaption Controls dialog box.
5.
Click
Mark to mark the cells for adaption (refinement/coarsening) by placing them in an adaption register (which can be manipulated as described in Section
27.11.1), or click
Adapt to perform the adaption immediately.
To disable refinement or coarsening, or marking for refinement or coarsening, turn off the
Refine or
Coarsen option before marking or adapting.