[ANSYS, Inc. Logo] return to home search
next up previous contents index

16.3.2 Specifying the Operating Pressure for the System

The system Operating Pressure is used to calculate density using the ideal gas law. When the Compressibility Effects option is enabled, the name Operating Pressure is changed to Equilibrium Operating Pressure since the non-premixed combustion model operating pressure can differ from the flow operating pressure. Section  16.2.2 provides more information about this value.

You can use the steady or unsteady laminar flamelet model for reactions in liquid systems. To do so, enable Liquid Micro-Mixing under PDF Options. The Liquid Micro-Mixing option is discussed in detail in this section in the separate Theory Guide.


next up previous contents index Previous: 16.3.1 Choosing Adiabatic or
Up: 16.3 Setting Up the
Next: 16.3.3 Specifying a Chemical
Release 12.0 © ANSYS, Inc. 2009-01-29