In the standard
-
model, you also have the option of including corrections to improve the accuracy in predicting free shear flows. The
Shear Flow Corrections option under the
k-omega Options is enabled by default in the
Viscous Model dialog box, as these corrections are included in the standard
-
model [
94]. When this option is enabled,
ANSYS FLUENT will calculate
using
this equation (in the separate
Theory Guide) and
using
this equation (in the separate
Theory Guide). If this option is disabled,
and
will be set equal to 1.