There are two ways you can specify transient cell zone and boundary conditions:
|
For both methods, the cell zone or boundary condition will vary only in time; it must be spatially uniform. However, if the in-cylinder model is activated (Section
11.3.6), then you have the option to use the crank angle instead of time. Crank angles can be included in transient tables as well as transient profiles, in a similar fashion to time. Examples of transient profiles and transient tables in crank angle can be found in the sections that follow.
|
Standard Transient Profiles
The format of the standard transient profile file (based on the profiles described in Section 7.6) is
((profile-name transient n periodic?) (field_name-1 a1 a2 a3 .... an) (field_name-2 b1 b2 b3 .... bn) . . . . (field_name-r r1 r2 r3 .... rn)) |
One of the field_names should be used for the time field, and the time field section must be in ascending order. n is the number of entries per field. The periodic? entry indicates whether or not the profile is time-periodic. Set it to 1 for a time-periodic profile, or 0 if the profile is not time-periodic.
An example is shown below:
((sampleprofile transient 3 0) (time 1 2 3 ) (u 10 20 30 ) ) |
This example demonstrates the use of crank angle in a transient profile
((example transient 3 1) (angle 0.000000e+00 1.800000e+02 3.600000e+02) (temperature 3.000000e+02 5.000000e+02 3.000000e+02) ) |
|
All quantities, including coordinate values, must be specified in SI units because
ANSYS FLUENT does not perform unit conversion when reading profile files. Also, profile names must have all lowercase letters (e.g.,
name). Uppercase letters in profile names are not acceptable.
|
You can read this file into ANSYS FLUENT using the Profiles dialog box or the File/Read/Profile... menu item.
Cell Zone Conditions Profiles...
Boundary Conditions Profiles...
File Read Profile...
See Section 7.6.3 for details.
Tabular Transient Profiles
The format of the tabular transient profile file is
profile-name n_field n_data periodic? field-name-1 field-name-2 field-name-3 .... field-name-n_field v-1-1 v-2-1 ... ... ... ... v-n_field-1 v-1-2 v-2-2 ... ... ... ... v-n_field-2 . . . . . v-1-n_data v-2-n_data ... ... ... ... v-n_field-n_data |
The first field name (e.g. field-name-1) should be used for the time field, and the time field section, which represents the flow time, must be in ascending order. The periodic? entry indicates whether or not the profile is time-periodic. Set it to 1 for a time-periodic profile, or 0 if the profile is not time-periodic.
An example is shown below:
sampletabprofile 2 3 0 time u 1 10 2 20 3 30 |
This file defines the same transient profile as the standard profile example above.
If the periodicity is set to 1, then n_data must be the number that closes one period.
An example is shown below:
periodtabprofile 2 4 1 time u 0 10 1 20 2 30 3 10 |
The following example uses crank angle instead of time:
example 2 3 1 angle temperature 0 300 180 500 360 300 |
|
All quantities, including coordinate values, must be specified in SI units because
ANSYS FLUENT does not perform unit conversion when reading profile files. Also, profile names must have all lowercase letters (e.g.,
name). Uppercase letters in profile names are not acceptable. When choosing the field names, spaces or parentheses should not be included.
|
You can read this file into ANSYS FLUENT using the read-transient-table text command.
file read-transient-table
After reading the table into ANSYS FLUENT, the profile will be listed in the Profiles dialog box and can be used in the same way as a boundary profile. See Section 7.6.3 for details.