33.16.4 Automatic Particle History Data Export Dialog Box
The
Automatic Particle History Data Export dialog box allows you to create an automatic particle history export definition for solution data. See Section
4.16.2 for details.
Controls
Name
specifies the name of the particle history export definition.
File Type
specifies the type of the file you want to write.
Standard
allows you to write the file in
FIELDVIEW format, which can be read in
FIELDVIEW.
EnSight
allows you to write the file in
EnSight format.
Injections
allows you to select the required injection from the list of predefined injections.
Quantity
contains the list of variables for which you can export the particle data.
Frequency (Time Steps)
specifies the number of particle time steps that are saved to the export file.
Separate Files for Each Time Step
allows you to have separate exported data files for each time step. Available only when
EnSight is selected as the
File Type.
Particle File Name
allows you to specify the file name/directory for the exported data, using the
Browse... button.
Ensight Encas File Name
is the file name you will specify if you selected
EnSight under
File Type. Use the
Browse... button to select the
.encas file that was created when you exported the file with the