33.16.4 Automatic Particle History Data Export Dialog Box

The Automatic Particle History Data Export dialog box allows you to create an automatic particle history export definition for solution data. See Section  4.16.2 for details.

figure

Controls

Name   specifies the name of the particle history export definition.

File Type   specifies the type of the file you want to write.
Standard   allows you to write the file in FIELDVIEW format, which can be read in FIELDVIEW.

EnSight   allows you to write the file in EnSight format.

Injections   allows you to select the required injection from the list of predefined injections.

Quantity   contains the list of variables for which you can export the particle data.

Frequency (Time Steps)   specifies the number of particle time steps that are saved to the export file.

Separate Files for Each Time Step   allows you to have separate exported data files for each time step. Available only when EnSight is selected as the File Type.

Particle File Name   allows you to specify the file name/directory for the exported data, using the Browse... button.

Ensight Encas File Name   is the file name you will specify if you selected EnSight under File Type. Use the Browse... button to select the .encas file that was created when you exported the file with the File/Export... menu option.


next up previous contents index Previous: 33.16.3 Automatic Export Dialog
Up: 33.16 Calculation Activities Task
Next: 33.16.5 Execute Commands Dialog