[ANSYS, Inc. Logo] return to home search
next up previous contents index


33.4.37 Single Rate Devolatilization Dialog Box

The Single Rate Devolatilization Model dialog box (which opens when you select single-rate as the Devolatilization in the Create/Edit Materials dialog box) allows you to input the parameters used in the single kinetic rate devolatilization model. See this section in the separate Theory Guide for details.

Note that the Single Rate Devolatilization Model dialog box is a modal dialog box, which means that you must tend to it immediately before continuing the property definitions.

figure

Controls

Pre-exponential Factor   sets the value of $A_1$ in this equation in the separate Theory Guide for the computation of the kinetic rate.

Activation Energy   sets the value of $E$ in this equation in the separate Theory Guide for the computation of the kinetic rate.


next up previous contents index Previous: 33.4.36 Gray-Band Refractive Index
Up: 33.4 Materials Task Page
Next: 33.4.38 Two Competing Rates
Release 12.0 © ANSYS, Inc. 2009-01-29