[ANSYS, Inc. Logo] return to home search
next up previous contents index


33.4.14 Power Law Dialog Box

The Power Law dialog box allows you to set the coefficients for the power law for viscosity. This dialog box will open when you select power-law in the drop-down list next to Viscosity in the Create/Edit Materials dialog box. See Section  8.4.2 for details about the items below.

figure

Controls

Methods   contains options for selecting the Two Coefficient Method or the Three Coefficient Method.

B   sets the coefficient $B$ in Equation  8.4-7 in SI units. This input will appear if you select the Two Coefficient Method.

Reference Viscosity   sets the reference viscosity $\mu_0$ in Equation  8.4-8. This input will appear if you select the Three Coefficient Method.

Reference Temperature   sets the reference temperature $T_0$ in Equation  8.4-8. This input will appear if you select the Three Coefficient Method.

Temperature Exponent   sets the temperature exponent $n$ in Equation  8.4-7 or 8.4-8, depending on your Method selection. If you are using the Two Coefficient Method, this input must be in SI units.


next up previous contents index Previous: 33.4.13 Sutherland Law Dialog
Up: 33.4 Materials Task Page
Next: 33.4.15 Non-Newtonian Power Law
Release 12.0 © ANSYS, Inc. 2009-01-29