[ANSYS, Inc. Logo] return to home search
next up previous contents index

6.2.6 Hooking DEFINE_DOM_SPECULAR_REFLECTIVITY UDFs

After you have interpreted (Chapter  4) or compiled (Chapter  5) your DEFINE_DOM_SPECULAR_REFLECTIVITY UDF, the name of the function you supplied as a DEFINE macro argument will become visible and selectable in the User-Defined Function Hooks dialog box (Figure  6.2.8) in ANSYS FLUENT.

figure   

The discrete ordinates (DO) radiation model must be enabled from the Radiation Model dialog box.

To hook the UDF to ANSYS FLUENT, open the User-Defined Function Hooks dialog box. (Figure  6.2.8)

Define $\rightarrow$ User-Defined $\rightarrow$ Function Hooks...

Figure 6.2.8: The User-Defined Function Hooks Dialog Box
figure

Select the function name (e.g., user_dom_spec_refl::libudf) in the DO Specular Reflectivity drop-down list in the User-Defined Function Hooks dialog box, and click OK.

See Section  2.3.4 for details about DEFINE_DOM_SPECULAR_REFLECTIVITY functions.


next up previous contents index Previous: 6.2.5 Hooking DEFINE_DOM_SOURCE UDFs
Up: 6.2 Hooking Model-Specific UDFs
Next: 6.2.7 Hooking DEFINE_EMISSIVITY_WEIGHTING_FACTOR UDFs
Release 12.0 © ANSYS, Inc. 2009-01-14