[ANSYS, Inc. Logo] return to home search
next up previous contents

Step 6: Cell Zone Conditions

figure Cell Zone Conditions

figure

1.   Set the conditions for the rotor fluid ( fluid-rotor).

figure Cell Zone Conditions figure figure fluid-rotor figure Edit...

figure

(a)   Enter -1 for Z in the Rotation-Axis Direction group box.

  According to the right-hand rule (see Figure  11.1), the axis of rotation is the $-Z$ axis.

(b)   Select Moving Reference Frame from the Motion Type drop-down list.

(c)   Enter 1800 rpm for Speed in the Rotational Velocity group box.

Hint:   Scroll down to locate the Speed text-entry box.

(d)   Click OK to close the Fluid dialog box.

2.   Set the conditions for the stator fluid ( fluid-stator).

figure Cell Zone Conditions figure figure fluid-stator figure Edit...

figure

(a)   Enter -1 for Z in the Rotation-Axis Direction group box.

(b)   Click OK to close the Fluid dialog box.


next up previous contents Previous: Step 5: Materials
Up: Using the Mixing Plane
Next: Step 7: Boundary Conditions
Release 12.0 © ANSYS, Inc. 2009-02-09