The default gradient limiter in ANSYS FLUENT is the Standard limiter. Each of the limiters is described in detail in this section in the separate Theory Guide. The gradient limiters are accessible from the Expert tab in the Advanced Solution Controls dialog box.
Solution Controls
Advanced...
You can select Standard, Multidimensional, or Differentiable from the Spatial Discretization Limiter Type drop-down list.
Each of these options can also be accessed using the TUI by typing the following command:
solve
set
slope-limiter-set
Choose from the following options:
Criterion | Type |
0 | Default(TVD) slope limiter |
1 | Multidimensional (TVD) slope limiter |
2 | Differentiable slope limiter |
Note that the Default(TVD) slope limiter in the TUI is equivalent to the Standard option in the GUI.
For each of the gradient limiter methods, ANSYS FLUENT provides two limiting directions: