For an effervescent atomizer injection, you will specify some of the same properties as for a plain-orifice atomizer. In addition to the position, axis (if 3D), temperature, mass flow rate (including both flashing and nonflashing components), duration of injection (if unsteady), vapor pressure, injector inner diameter, and azimuthal angles (if relevant) described in Section 23.3.7, you will need to specify the following parameters under Point Properties:
Set the mass fraction of the injected mixture that vaporizes in the
Mixture Quality field (
in
this equation in the separate
Theory Guide).
Set the saturation temperature of the volatile substance in the Saturation Temp. field.
Set the parameter that controls the spatial dispersion of the droplet sizes in the
Dispersion Constant field (
in
this equation in the separate
Theory Guide).
Set the initial trajectory of the film as it leaves the end of the orifice in the Maximum Half Angle field.
See this section in the separate Theory Guide for details about how these inputs are used.