14.6.1 Total Heat Rejection Rate

To postprocess the total heat rejection rate, you can set up a volume monitor to monitor convergence and view the computed values.

figure Monitors (Volume Monitors) figure Create...

1.   Select Sum from the Report Type drop-down list.

2.   Select Temperature and Heat Exchanger Source fom the Field Variables drop-down lists.

3.   Select the appropriate Cell Zones and click OK to close the Volume Monitor dialog box.

Figure 14.6.1: The Volume Monitor Dialog Box
figure

figure   

Note that the macro heat exchangers contain only the primary fluid as the cell zone, but in case of the dual cell model, you can select either the primary or auxiliary fluid.