The
Adapt/Smooth/Swap... menu item opens the
Smooth/Swap Mesh dialog box. This menu item is not available in parallel
ANSYS FLUENT.
Smooth/Swap Mesh Dialog Box
The
Smooth/Swap Mesh dialog box controls smoothing and face swapping of the numerical mesh. See Section
27.13 for details about the items below.
Controls
Smooth
contains parameters associated with smoothing the mesh.
Method
indicates whether the Laplacian or the skewness-based smoothing method is to be used. Select
laplace or
skewness from the drop-down list.
Relaxation Factor
(for Laplacian smoothing) sets the factor by which to multiply the computed position increment for the node. The lower the factor, the more reduction in node movement. This field appears when
laplace is selected as the smoothing method.
Minimum Skewness
(for skewness-based smoothing) sets the minimum cell skewness value for which node smoothing will be attempted.
ANSYS FLUENT will try to move interior nodes to improve the skewness of cells with skewness greater than this value. By default,
Minimum Skewness is set to 0.8 for 3D or 0.4 for 2D. The
Minimum Skewness field appears when
skewness is selected as the smoothing method.
Number of Iterations
defines the number of successive smoothing sweeps performed on the mesh.
Swap Info
provides information on the most recent face-swapping operation.
Number Swapped
displays the number of faces that were swapped based on the Delaunay circle test.
Number Visited
displays the total number of faces that were visited and tested for possible face swapping.
Smooth
initiates the desired number of smoothing iterations.
Swap
exchanges the faces of cells for which the circle test is not satisfied.