The
Define/User-Defined/Function Hooks... menu item opens the
User-Defined Function Hooks dialog box.
User-Defined Function Hooks Dialog Box
The
User-Defined Function Hooks dialog box allows you to specify user-defined functions (UDFs) connected to a number of models and procedures in
ANSYS FLUENT. See the separate
UDF Manual for details.
You can hook multiple UDFs to the following functions:
Controls
Initialization
Adjust
Execute At End
Read Case
Write Case
Read Data
Write Data
Execute at Exit
Controls
Initialization
selects a UDF that is called immediately after you initialize your flow field.
Adjust
selects a UDF that is called at the beginning of an iteration before solution of velocities, pressure, and other quantities begins.
Execute At End
selects a UDF that is called at the end of an iteration or time step.
Read Case
selects a UDF that defines a customized section that is to be read from the case file.
Write Case
selects a UDF that defines a customized section that is to be written to the case file.
Read Data
selects a UDF that defines a customized section that is to be read from the data file.
Write Data
selects a UDF that defines a customized section that is to be written to the data file.
Execute at Exit
selects a UDF that is called when exiting a
ANSYS FLUENT session.
Wall Heat Flux
selects a UDF that modifies the way that the solver computes the heat flux between a wall and the neighboring fluid cells.
Net Reaction Rate
selects a UDF that defines the net reaction rate.
Volume Reaction Rate
selects a UDF that defines a volumetric reaction rate.
Surface Reaction Rate
selects a UDF that defines a surface reaction rate.
Particle Reaction Rate
selects a UDF that defines a particle reaction rate.
Turbulent Premixed Source
selects a UDF that defines the turbulent flame speed and source term for the premixed or partially premixed combustion model.
Chemistry Step
selects a UDF that defines the chemistry step function.
Spray Collide
selects a UDF that defines the spray collide function.
Cavitation Mass Rate
selects a UDF that defines the cavitation rate.
DO Source
selects a UDF that defines the discrete ordinate source function.
DO Diffuse Reflectivity
selects a UDF that defines the diffuse reflectivity function for the DO radiation model.
DO Specular Reflectivity
selects a UDF that defines the specular reflectivity function for the DO radiation model.
DO Emissivity Weighting Factor
selects a UDF that defines the emissivity weighting factor for the non-gray DO radiation model.