$$$$ POT_VECT NOTICE CHAT 11/09/12 21:17:42 7124 DATE 11/09/12 Procedure POT_VECT Voir aussi : ------------------ POT_VECT TAB1 (MOT1) Description : ------------- In 2D magnetostatics, calculation of the vector potential TAB1 table with the following data : 'MUAIR' air permeability (by default meter unit) 'AIR' part of the air which is not reduced to a super element |'AIRSUP' part of the air treated as a super element (optional) optional |'MAITRES' master points if super element |'ENCS ' boundary condition on super element (possibly) 'TABNUSEC' = TABMAT table containing tables descripting Ferro_magnetique(s) domains as following : |MODI = MODE GEO1 THERMIQUE ISOTROPE (ORTHOTROPE) |TABMAT.MODI = STN ; |STN = TABLE ; |STN.'EV1' = MU1(H) curve 1./MU0*MUREL(B) type evolution Imat times|can be obtained whith H_B procedure | if orthotropic material |STN.'DIR1' = P1 direction ( type point) |STN.'EV2' = MU2(H) curve 1./MU0*MUREL(B) type evolution | in orthogonal direction 'BLOQUE ' general boundary conditions put together 'IMPOSE' CHPOINT (created by DEPIMP, the stiffness part must be in MATAB.'BLOQUE') 'COUR' table of tables containing a description of the blocks of electric current obtained when calling on the DESCOUR procedure 'AXI' = VRAI (true) if axisymmetrical problem MOT1 optional word 'SOLIN' for the calculation of the first linear step Output data : 'POTENTIEL' if the calculation of the first step is requested to be performed by SOLIN TABB contains data required by the MAG_NLIN procedure for performing non linear calculations (see MAG_NLIN).