Download gmv.notice

Back to the list

Display this manual page in
$$$$ GMV      NOTICE  CHAT      11/09/12    21:16:24     7124           
                                             DATE     11/09/12

  Operateur GMV (Groupe Moto Ventilateur) Voir aussi :
     -------------   



     Description : Discretizes a momentum source term.
             Either the value of this source term is imposed
             or this source term is calculated in relation to
             the GMV characteristics (flow-pressure curve)
             supplied by the user.


     Syntax (EQEX) :

              GMV TABGMV  INCO 'UN'

     TABGMV : Table containing the following inputs

    'DIR'       POINT         impulse direction
    'PENTREE'   LISTENTI      elements number (GMV zone)
                              for computing input pressure
    'PSORTIE'   LISTENTI      elements number (GMV zone)
                              for computing output pressure
    'LDEBIT'    MAILLAGE      line (2D) for pressure calculation

    <'KIMP'>    FLOTTANT      imposed impulse (its value)
    <'IMPR'>    ENTIER        data print frequency on the GMV
                              running point 

    If 'KIMP' input lacks :

     'GMV'      EVOLUTION     GMV flow-pressure curve
    <'OMEGA'>   FLOTTANT      relaxation factor (default 0.5)
    <'K0'>      FLOTTANT      K value of initialization 
                              (this value is updated at each new step)

    Example : See the HY2.dtc data sets.




 