Download mag_nlin.notice

Back to the list

Display this manual page in
$$$$ MAG_NLIN NOTICE  CHAT      11/09/12    21:17:08     7124           
                                             DATE     11/09/12
 
  Procedure   MAG_NLIN                   Voir aussi :
      --------------------   
          MAG_NLIN TABB 


       Description :
       -------------

       Calculation of non-linear vector or scalar potential 
       for magnetostatic problems 2D and 3D 


       Contents :
       ----------

        
       Some arguments of the TABB table are constructed after
       running into the POT_VECT or POT_CSAL procedures.
       

       Other specific arguments of the MAG_NLIN procedure :
 
       TABB     table type object with the following indices
                written in words

 
   Compulsory :
   
        'SOUSTYPE'     THERMIQUE                                  
        'EVOCOND'      Evolution of Mu created by the H_B procedure
                       which gives the curve ad hoc for POT_VECT or
                       POT_SCAL 
  
 
   Optional    :
                                                      
        'CRITERE'      Convergence criterion (10E-5 by default)
        'OME'          Oscillation damping coefficient  0< OME < 1.
                       mainly for 2D 
        'NITER'        Updating of conductivity every NITER 
                       iterations (NITER=1 by default)
        'NIVEAU'       Level of messages (NIVEAU=0 by default)
        'ITERMAX'      Maximum number of iterations
                              (ITERMAX=10 by default)
   Arguments created during the call on POT_VECT or POT_SCAL
   

        'FLUX'         Equivalent flux                 
        'CLIM'         Restraint matrix (created by BLOQUE  T)
        'IMPOSE'       Imposed values (created by DEPI) 
        'RIGCON '      Constant stiffness               
        'RIGFER '      Variable stiffness 
                   
     ETAB contains on output : :
                               
        'POTENTIEL'    Outcoming potential            



 
 