$$$$ FFOR NOTICE PV 13/12/03 21:15:01 7875 DATE 13/12/03 Operateur FFOR Voir aussi : MODE RAYE -------------- RAYN CH2 = FFOR MODL1 CHE1 ; Description : ____________ This operator calculates the view factors matrix corresponding to a geometry that discretizes an enclosure. Contents : _________ MODL1 : modeled structure (MMODEL type) CHE1 : MCHAML object of materials (coefficient of absorption if needed) Notes : ______ 1. The trigonometric orientation of the elements (associated to the order of description of the nodes in each element) defines a normal direction which must correspond to the radiating side. This condition is absolutely necessary. 2. The revolution axis (in cylindrical geometry) must not be meshed. An symetry axis must not be meshed. 3. The option 'SYME' is not available in cylindrical geometry (in order to define an axis different from the revolution axis). 4. The option IMPI of operator OPTI gives the errors made on the balances and the reciprocity conditions 5. In case of a participating medium the absorption coefficient must be negative. The enclosure is at a uniform temperature and does not scatter. This option is not compatible with the options 'SYME' or 'CVXE'. 6. The unity for the temperature is the degree Kelvin. (cf. operator RAYN).