$$$$ FILTREKE NOTICE CHAT 11/09/12 21:16:12 7124 DATE 11/09/12 Procedure FILTREKE Voir aussi : ------------------ SYNTAXE ( EQEX ) : Cf operateur EQEX _________________ 'OPER' 'FILTREKE' U0 L0 NU UN 'INCO' 'KN' 'EN' Description : _____________ This procedure filters the K and epsilon values computed by the K - epsilon turbulence model. The prescribed constraints are : 0 < k < Max(UN,U0)**2 k > 0 , epsilon > Cnu * k**1.5 / L0 > 0 where Cnu = 0.09 is a constant of the K-epsilon model. U0 is a reference velocity which limits the turbulence intensity. L0 is a maximum length scale. => Nut < U0*L0 Comments : __________ U0 Reference Velocity FLOTTANT ou MOT L0 Length scale FLOTTANT ou MOT NU kinematic viscosity FLOTTANT ou MOT UN Velocity field CHPOINT VECT SOMMET ou MOT A type MOT coefficient indicates that the operator search for the coefficient in the INCO table referenced by the given MOT.