$$$$ FILTREKE NOTICE  CHAT      11/09/12    21:16:12     7124           
                                             DATE     11/09/12

  Procedure FILTREKE                       Voir aussi :
    ------------------    
    SYNTAXE ( EQEX ) : Cf operateur EQEX
    _________________

    'OPER' 'FILTREKE' U0 L0 NU UN 'INCO' 'KN' 'EN'
     
       

 
    Description :
    _____________
                                                                                
 This procedure filters the K and epsilon values computed by the
 K - epsilon turbulence model.
 The prescribed constraints are :
 0 < k < Max(UN,U0)**2
 k > 0 , epsilon > Cnu * k**1.5 / L0  > 0
 where Cnu = 0.09 is a constant of the K-epsilon model.
 U0 is a reference velocity which limits the turbulence intensity.
 L0 is a maximum length scale.
 => Nut < U0*L0

                                                                                
                                                                                
    Comments :
    __________
                                                                                
                                                                                
                                                                                
    U0     Reference Velocity
           FLOTTANT ou MOT
                                                                                
    L0     Length scale
           FLOTTANT ou MOT

    NU     kinematic viscosity
           FLOTTANT ou MOT
                                                                                
    UN     Velocity field
           CHPOINT VECT SOMMET ou MOT

 A type MOT coefficient indicates that the operator search for the coefficient
 in the INCO table referenced by the given MOT.

 
 

© Cast3M 2003 - All rights reserved.